Multi-Operator Fume Extractors, manufactured by Sentry Air Systems, are portable or stationary fume extractors with more than one exhaust hose attached to the system with the ability to simultaneously extract fume, dust, and particulate matter. The source-capture arms on these units can be taken on and off depending upon the user's needs. Accessories, like end caps, are available to block inlet ports at the base of the unit if all flex arms are not required for operation.
Multi-Operator fume extractors are air filtration systems designed to provide portable fume extraction to two or more operators simultaneously. Multiple flame-retardant, self-supportive flex arms provide equal suction at all inlets, which directs contaminants into the exhaust engineering control.
Sentry Air Systems Multi-Operator Fume Extractors are designed and manufactured to provide multiple outlets to perform applications that require filtration at separate working stations. In some cases housing multiple air filtration systems can be bulky, aesthetically displeasing, or not feasibly applicable to allotted square footage; in these instances, it is recommended that a multi operator fume extractor be implemented as safety control against dust and particulates.
There are many applications that fit the use of a Multi-Operator Fume Extractors, typical uses include:
Optional HEPA, ULPA, and charcoal filters are available for more demanding industrial ventilation system applications. However, in most cases, speaking with a subject matter expert to determine whether or not your application requires a Multi-Operator Fume Extractor is advisable.
Cabinet Dimensions:
- 10.5"L x 8"W x 10.5"H
Cabinet Material:
16 ga. carbon steel
Arm Dimension:
- (2) 3" Round x 52" Long
Motor:
Fractional Horsepower
Weight:
Approx. 12 lbs.
Air Volume:
Up to 80 CFM
Electrical:
115/1/60, .3 amps
220/1/50, .2 amps
Sound Level:
56 dba @ 3 ft. from hood inlet
Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
Patented Design:
U.S. PATENT #5,843,197
Cabinet Dimensions:
- 10.5"L x 8"W x 10.5"H
Cabinet Material:
16 ga. carbon steel
Arm Dimension:
- (2) 3" Round x 52" Long
Motor:
Fractional Horsepower
Weight:
Approx. 12 lbs.
Air Volume:
Up to 91 CFM
Electrical:
115/1/60, .46 amps
Sound Level:
64 dba @ 3 ft. from hood inlet
Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
Patented Design:
U.S. PATENT #5,843,197
Cabinet Dimensions:
- 15.5"L x 13"W x 16.5"H
Cabinet Material:
16 ga. carbon steel
Arm Dimension:
- (2) 4" Round x 48" Long fire retardant flex hose
Motor:
Fractional Horsepower
Total Weight:
40 to 55 lbs.
Approximate Inlet Velocities:
Pre-filter & 99.97% HEPA Filter - 100 FPM
Pre-filter & Heavy-duty Carbon Filter - 60 FPM
Electrical:
115/1/60, 2 amps
220/1/50, .75 amps
Sound Level:
61 to 66 dba (Blower Speed: Low to High)
Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
Warranty:
Limited two-year warranty from date of shipment on defects due to materials or workmanship.
Patented Design:
U.S. PATENT #5,843,197
U.S. PATENT #8,353,745
Cabinet Dimensions:
- 22.5"L x 20"W x 21.5"H
Arm Dimension:
- (2) 5" Round x 48" Long fire retardant flex hose
Total Weight:
- 60 to 110 lbs
Cabinet Material:
- 16 ga. carbon steel
Air Volume:
Variable Speed Control Standard
700 CFM High, Down to 50 CFM Low
Electrical:
115/1/60, 2.5 amps
220/1/50 or 60, 1.5 amps
Sound Level:
Approx. 60 dba @ 3'
Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
Patented Design:
U.S. PATENT #5,843,197
U.S. PATENT #8,353,745
Cabinet Dimensions:
- 22.5"L x 20"W x 20"H
Arm Dimension:
- (2) 5" Round x 48" Long fire retardant flex hose
Total Weight:
- 62 to 112 lbs.
Cabinet Material:
- 16 ga. carbon steel
Air Volume:
Variable Speed Control Standard
877 CFM High, Down to 0 CFM Low
Electrical:
115/1/60, 5.2 amps
Sound Level:
71 dba @ 3 ft.
Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
Patented Design:
U.S. PATENT #5,843,197
U.S. PATENT #8,353,745
Cabinet Dimensions:
- 30” D x 30” W x 42.5” H
Cabinet Material:
- 16 ga. carbon steel
Arm Specifications:
- (2)7” Diameter, 7’ L
- Rigid segment: Aircraft-grade aluminum
- 6” diameter Flexible segment: Black Flex Sentry™
- 10" round capture hood
Total Weight:
Approximately 265lbs without Filters
Approximately 345lbs with Filters Installed
Motor:
Fractional Horsepower
Air Volume:
500 Series: Up to 389 CFM (MP1 filters)
550 Series: Up to 478 CFM (MP1 filters)
Electrical:
500 Series: 115/1/60, 2.5 amps; 220/1/50, 1.5 amps
550 Series: 115/1/60, 5.7 amps
Sound Level:
500 Series: 65 dba @ 3’ from hood inlet
550 Series: 70 dba @ 3’ from hood inlet
Warranty:
Limited two-year warranty from date of shipment on defects due to materials or workmanship.
Patented Design:
U.S. PATENT #61,563,228
Cabinet Dimensions:
- 15.5"L x 13"W x 16.5"H
Arm Dimension:
- (4) 3" Round x 48" Long fire retardant flex hos
Cabinet Material
ABS Plastic & Aluminum
Motor:
Fractional Horsepower
Total Weight:
50 to 60 lbs.
Air Volume:
Variable Speed Control Standard
85 CFM High, Down to 50 CFM Low Per Arm
Electrical:
115/1/60, 2 amps
220/1/50, .75 amps
Sound Level:
61 to 66 dba (Blower Speed: Low to High)
Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
Warranty:
Limited two-year warranty from date of shipment on defects due to materials or workmanship.
Patented Design:
U.S. PATENT #5,843,197
U.S. PATENT #8,353,745
Cabinet Dimensions:
- 22.5"L x 20"W x 21.5"H
Cabinet Material:
- 16 ga. carbon steel
Arm Specifications:
- (4) 4" Round x 48" Long fire retardant flex hose
Total Weight:
- 60 to 110 lbs
Air Volume:
Variable Speed Control Standard
700 CFM High, Down to 50 CFM Low
Sound Level:
Approx. 60 dba @ 3'
Electrical:
115/1/60, 2.5 amps
220/1/50 or 60, 1.5 amps
Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
Patented Design:
U.S. PATENT #5,843,197
U.S. PATENT #8,353,745
Cabinet Dimensions:
- 22.5"L x 20"W x 20"H
Cabinet Material:
- 16 ga. carbon steel
Arm Specifications:
- (4) 4" Round x 48" Long fire retardant flex hose
Total Weight:
- 62 to 112 lbs.
Air Volume:
Variable Speed Control Standard
877 CFM High, Down to 0 CFM Low
Electrical:
115/1/60, 5.2 amps
Sound Level:
71 dba @ 3 ft.
Max Operating Temperature:
Not to exceed 170 degrees Fahrenheit
Patented Design:
U.S. PATENT #5,843,197
U.S. PATENT #8,353,745
Dual 200
|
Dual 300
|
Dual 400
|
Dual 500
|
Quad 300
|
Quad 400
|
|
---|---|---|---|---|---|---|
Cabinet Dimensions: | 10.5"L x 8"W x 10.5"H | 15.5"L x 13"W x 16.5"H | 22.5"L x 20"W x 19.5"H | 30” D x 30” W x 42.5” H | 15.5"L x 13"W x 16.5"H | 22.5"L x 20"W x 19.5"H | CFM: (per arm) |
Up to 50 CFM | Up to 175 CFM | Up to 350 CFM | 500 Series: Up to 389 CFM 550 Series: Up to 478 CFM |
Up to 85 CFM | Up to 175 CFM | Filter Size: | Small | Medium | Large | Extra Large | Cleanable | Medium | Large |
Weight: | Approx. 12 lbs. | Approx. 40 to 55 lbs. | 50 to 100 lbs |
Approx. 265 lbs w/out Filters Approx. 362 lbs w/ Filters |
50 to 60 lbs. | 50 to 100 lbs |
Electrical |
115/1/60, .3 amps 220/1/50, .2 amps |
115/1/60, 2 amps 220/1/50, .75 amps |
400 Series: 115/1/60, 2.5 amps 220/1/50 or 60, 1.5 amps 450 Series: 115/1/60, 5.2 amps |
500 Series:
115/1/60, 2.5 amps
220/1/50, 1.5 amps
550 Series: 115/1/60, 5.7 amps |
115/1/60, 2 amps 220/1/50, .75 amps |
400 Series: 115/1/60, 2.5 amps 220/1/50 or 60, 1.5 amps 450 Series: 115/1/60, 5.2 amps |
Sound Level | 56 dba @ 3 ft. from hood inlet | 61 to 66 dba (Blower Speed: Low to High) | 60 dba @ 3 ft. | 500 Series: 65 dba @ 3’ from hood inlet 550 Series: 70 dba @ 3’ from hood inlet |
61 to 66 dba (Blower Speed: Low to High) | Approx. 60 dba @ 3' |
SS-000-HC
Displays hours unit has
been in operation.
SS-005-CAP
Blocked unused inlets
SS-300-MAG
Monitors filter saturation